Lab Machines
SHORT TIME CURRENT & CURRENT CYCLING - TEST APPARATUS
- Test setup adheres to the standard UL 467 clause 7.5 & 9.5.& 486A-486B Clause 7.2 & 3
- The set-up consists of a True RMS Constant Current Source (to maintain the Current within + / – 1 % of set value with Digital Indication), PC based control system.
- Input Supply: Three Phase 415 VAC, 600 Amps CONST. (1200 S.T.) for 2 Phase @ 50 Hz.
- Output: Current Source 50A to 10KA Continues & 25KA 9 Sec.
- Current Test (CT) selection Range – 200A, 500A, 1KA, 2KA, 5KA, 10KA, 20KA, 30KA.
- Provided with safety guard (chamber) to prevent fire hazards.
- Two operating modes are provided: PC & MANUAL.
- Selection of output voltages, the ranges are 5.0 V,4.0 V, 5.0V, 6V selection through switches.
- 7 Channels, Cr/Al type Thermocouple sensor for temperature sensing & one is RTD PT100 for Ambient with PC datalogging.
- Servo controlled mechanism for maintaining the Test Current at preset value in manual mode.
SHORT TIME CURRENT & CURRENT CYCLING - TEST APPARATUS
- Test setup adheres to the standard UL 486A-486B clause 7.2 & 7.3 (current- cycling and Static –heating sequence).
- The set-up consists of a True RMS Constant Current Source (to maintain the Current within + / – 1 % of set value with Digital Indication), PC based control system.
- Input Supply: Three Phase 415 VAC, 120 amp @ 50 Hz.
- Output: Current Source 50A to 4 KA @ 60 Hz.- frequency converted by frequency converter (Q-Shine).
- Current Test (CT) selection Range – 200A, 500A, 1000A, 2000A, 4000A.
- Provided with Vertical loop stand to preform the test.
- Three operating modes are provided: PC, PLC & MANUAL.
- Selection of output voltages, the ranges are 3 V,4.5 V,4.5 V selection through switches.
- 4 Channels, Cr/Al type Thermocouple with one RTD PT 100 sensor for temperature sensing with PC datalogging.
- Servo controlled mechanism for maintaining the Test Current at preset value in manual mode.
SECURENESS- TEST APPARATUS
- Test setup adheres to the standard UL 486A-486B clause 9.3.2..
- Input Supply: Three Phase, neutral and earthing (10A)@ 50 Hz.
- Equipment is 4 stations where can perform the test 4 sample at a me to manage the testing me.
- Bush sizes are available from range 6.4 mm ( 18 AWG wire) to 54 mm ( 2000 kcmil) each 4 sets total 60 nos. for 15 sizes of conductors.
- Dead weights are available 15 nos. each 4 sets from 0.1 kg to 50 kg, total 60 nos.
- Test capacity for; size of conductors 18 AWG – to- 2000 kcmil & Mass 0.9 kg(2 lb.) –to -109 kg (240 lb.)
- Bushes, Dead weights and me & count are NABL calibrated.
- Motorised mechanism.
- Rotation speed controllable as per standard.
- Digital display for shows the count and me ( Seconds) at the me of testing & inbuilt Sencers for count and me.
- Height can be adjustable as per standard table 26.
PULLOUT - TEST APPARATUS
- Test setup adheres to the standard UL 486A-486B clause 9.3.4..
- Input Supply: Single Phase with neutral and earthing @ 50 Hz.
- Machine is adjustable height screw type.
- Upper Clamp with load cell, lower for pull and push.
- Test capacity is up to 1000 kg (2204 lbs.) with pick value measurement digital indicator unit.
- Load cell and software time are NABL calibrated.
- Pick load mode unit Kg. having both push & pull facilities
- Motorize Mechanism operate by control panel.
- PC base machine operation by using Pullout Test V 1.0 software.
- Test report can be generated atier comple on of the test.
- Test report will be generated in PDF format